Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
1.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1421833

ABSTRACT

Posterior a un tratamiento endodóntico, muchas veces el remanente es insuficiente para la retención de un material de restauración, por este motivo es necesario la colocación de un sistema de poste-muñón para otorgar retención a la restauración final. Con la aparición de diversos materiales para las restauraciones estéticas, se utilizan actualmente resinas reforzadas con fibra de vidrio como sistemas de postes y muñones para la restauración de dientes tratados endodónticamente. El objetivo del presente trabajo fue comparar la fuerza de adhesión en la prueba push-out de dos diferentes tipos de postes de fibra de vidrio; 3M RelyX y Rebilda Post GT (VOCO) adheridos con cementos duales correspondientes a la marca de los postes; RelyX U-200® Automix (3M ESPE) y Rebilda DC (VOCO). Se llevó a cabo un análisis de ANOVA de dos vías para comparar la fuerza adhesiva con la prueba push-out entre ambos grupos de estudio. Pese a que se observó que los postes Rebilda presentaron una media de fuerza de adhesión ligeramente mayor en comparación con los postes 3M (sin diferencia estadística significativa P>0,05) los últimos son clínicamente más fáciles de colocar, lo cual pudiera ser un factor decisivo para el clínico en el momento de la elección de un poste y su sistema de adhesión.


After an endodontic treatment, many times the remnant is insufficient for the retention of a restorative material, for this reason it is necessary to place a post-stump system to provide retention to the final restoration. With the advent of various materials for esthetic restorations, fiberglass-reinforced resins are now used as post and core systems for the restoration of endodontically treated teeth. The objective of the present work was to compare the bond strength in the push-out test of 2 different types of fiberglass posts; 3M RelyX and Rebilda Post GT (VOCO) bonded with dual cements corresponding to the post brand; RelyX U-200® Automix (3M ESPE) and Rebilda DC (VOCO). A 2-way ANOVA analysis was performed to compare push-out strength between both study groups. Although it was observed that the Rebilda posts presented a slightly higher mean bond strength compared to the 3M posts (with no significant statistical difference P>0.05), the latter are clinically easier to place, which could be a decisive factor for the clinician at the time of choosing a post and its adhesion system.

2.
Braz. dent. j ; 33(2): 91-98, Mar.-Apr. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1374624

ABSTRACT

Abstract This study aimed to evaluate the influence of calcium silicate-based sealers on the bond strength of fiber posts using conventional and self-adhesive resin cement. Sixty single-rooted teeth were selected. The canals were prepared with a reciprocating instrument 40.06. The roots were randomly distributed in six groups (n = 10) according to the strategies for root canal filling and fiber posts cementation: AH Plus/RelyX ARC; AH Plus/RelyX U200; Bio C Sealer/RelyX ARC; Bio C Sealer/RealyX U200; Sealer Plus BC/RelyX ARC; and Sealer Plus BC/RelyX U200. The roots were transversally sectioned, and one slice per post-third was obtained. The push-out test was performed at a crosshead speed of 1mm/min. The failure patterns were described after assessment with a stereomicroscope with a 10× magnification. Bond strength was calculated and analyzed using the ANOVA and Tukey test. AH Plus did not influence the bond strength of fiber posts cemented with conventional (RelyX ARC) or with self-adhesive resin cement (RelyX U200). The lowest bond strength values were obtained when calcium silicate-based sealers were associated with conventional resin cement (Bio C Sealer/RelyX ARC and Sealer Plus BC/RelyX ARC). Except for Sealer Plus BC/RelyX ARC, all groups presented lower bond strength at the apical portion compared to the cervical portion of the post. Adhesive failures between cement and post and cement and dentin were predominant (55.3%). Calcium silicate-based sealers decreased the bond strength of fiber posts cemented with conventional resin cement.


Resumo Este estudo teve como objetivo avaliar a influência de cimentos à base de silicato de cálcio na resistência de união de pinos de fibra utilizando cimentos resinosos convencionais e autoadesivos. Sessenta dentes humanos monorradiculares foram selecionados. Os canais foram preparados um instrumento reciprocante 40.06. As raízes foram distribuídas aleatoriamente em seis grupos (n = 10) de acordo com as estratégias de obturação do canal e cimentação dos pinos de fibra: AH Plus/RelyX ARC; AH Plus/RelyX U200; Bio C Sealer/RelyX ARC; Bio C Sealer/RealyX U200; Sealer Plus BC/RelyX ARC; e Sealer Plus BC/RelyX U200. As raízes foram seccionadas transversalmente e foi obtido um espécime por terço. O teste de push-out foi realizado em uma velocidade de 1mm/min. Os padrões de falha foram descritos após avaliação em estereomicroscópio com aumento de 10×. A resistência de união foi calculada e analisada por ANOVA e teste de Tukey. AH Plus não influenciou na resistência de união dos pinos de fibra cimentados com cimento resinoso convencional (RelyX ARC) ou autoadesivo (RelyX U200) (p > 0,05). Os menores valores de resistência de união foram obtidos quando os cimentos à base de silicato de cálcio foram associados ao cimento resinoso convencional (Bio C Sealer/RelyX ARC e Sealer Plus BC/RelyX ARC) (p < 0,05). Com exceção do Sealer Plus BC/RelyX ARC, todos os grupos apresentaram menor resistência de união na porção apical em comparação com a porção cervical do pino (p < 0,05). Falhas adesivas entre cimento e pino e cimento e dentina foram predominantes (55,3%). Cimentos a base de silicato de cálcio diminuíram a resistência de união de pinos de fibra cimentados com cimento resinoso convencional.

3.
Odovtos (En línea) ; 23(1)abr. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386520

ABSTRACT

Abstract: This study evaluated the biomineralization processes and push-out strength of MTA Flow® with radicular dentine in three different consistencies. The push-out test was performed on an ex vivo model, using 2mm thick dentin discs from the middle third of the root with standardized cavities of 1.5 mm. Samples were filled with MTA-Angelus (Angelus Dental, Brazil), Biodentine (Septodont, France), MTA Flow® Putty (Ultradent, USA), MTA Flow® Thick or MTA Flow® Thin. The samples were divided into 3 groups: subgroup 1 (n=5), analysis of the biomineralization process; 2 (n=20), evaluation of the bonding strength and push-out resistance; and 3 (n=5), evaluation of the cement/ dentin interface. The samples filled with Biodentine had a higher precipitation of carbonate apatite. However, there was no significant difference between MTA-Angelus, MTA Flow® Putty, or Thick (p=0.0536), but there was a significant difference in the Thin group (P<0.05). The samples with Biodentine displayed the greatest release of calcium ions. The formation of a partially carbonated intermediate apatite layer was observed in all groups. Zones of biomineralization were observed at the interface but were not continuous. After 72 hours, a significant difference was found between the Biodentine and MTA Flow® Thin groups (p=0.0090) in the push-out test. The samples submerged in phosphate-buffered saline (PBS) for 15 days showed a significant difference between all groups and MTA Flow® Thin (p=0.0147). Putty or Thick consistencies presented a similar bonding strength to MTA-Angelus and Biodentine. MTA Flow® Putty and Thick consistencies show a good adaptation to dentin, similar to MTA-Angelus. However, the thickness of the interface was lower compared to that of Biodentine. MTA Flow® Thin, despite their tubular infiltration, results in gaps and a defective peripheral seal.Therefore, MTA Flow®, in Putty or Thick consistencies, presents a biomineralization process and push-out strength similar to MTA Angelus and Biodentine, however, both characteristics decreases considerably in Thin consistency.


Resumen: El objetivo de este estudio fue evaluar, en un modelo ex vivo, el proceso de biomineralización y fuerza de adhesión del MTA Flow® en sus tres diferentes consistencias por medio de la prueba de resistencia al desplazamiento (Push-out). Se utilizaron discos de dentina de 2mm de espesor del tercio medio radicular con cavidades estandarizadas de 1.5mm de diámetro, las cuales se obturaron con diferentes materiales entre ellos: MTA Angelus (Angelus Dental, Brasil), Biodentine (Septodont, Francia), MTA Flow® Consistencia Putty (Ultradent, E.E.U.U), MTA Flow® Consistencia Thick (Ultradent, E.E.U.U) y MTA Flow® Consistencia Thin (Ultradent, E.E.U.U). Las muestras se sometieron al proceso de biomineralización y a pruebas de Push-out. Las muestras obturadas con Biodentine promovieron una mayor precipitación de apatita carbonatada, sin embargo, no se presentó diferencia estadística significativa con respecto al MTA Angelus, MTA Flow® Putty ni Thick (p=0.0536). No obstante, si presentó una diferencia significativa con respecto al grupo de MTA Flow® consistencia Thin (P<0.05). Las muestras con Biodentine presentaron la mayor liberación de iones calcio. De acuerdo a las pruebas de resistencia al desplazamiento, a las 72 horas post-obturación, solamente se encontró diferencia significativa entre las muestras obturadas con Biodentine y las correspondientes al MTA Flow consistencia Thin (p=0.0090), sin embargo las muestras sumergidas 15 días en PBS presentaron diferencia significativa entre todos los grupos con respecto al MTA Flow Thin (p=0.0147). En general se observaron zonas de biomineralización en la interface, sin embargo, no fueron continuas. Se concluye que el MTA Flow en consistencia Putty o Thick presenta un proceso de biomineralización y una resistencia al desplazamiento similar al MTA Angelus y al Biodentine, sin embargo, esta última disminuye considerablemente en presentación Thin.


Subject(s)
Apatites , Biomineralization
4.
Rev. Fac. Odontol. (B.Aires) ; 36(82): 35-42, 2021. ilus, tab, graf
Article in Spanish | LILACS | ID: biblio-1291352

ABSTRACT

En los últimos años resulta de elección la utilización de postes de fib ra en la rehabilitación de piezas endodónticamente tratadas. La adhesión entre poste, agente cementante y dentina radicular permitiría lograr una retención de la estructura dentro de las paredes del conducto. El objetivo de este estudio fue comparar la resistencia adhesiva en los tercios cervical, medio y apical, entre la dentina del conducto radicular y el cemento adhesivo utilizado en la cementación de postes de fibra. Se utilizaron 30 premolares inferiores uniradiculares humanos, recientemente extraídos, se realizaron los tratamientos endodónticos, se desobturaron y realizaron las preparaciones con la fresa conformadora número 3 para la cementación de postes White Post DC especial número 3 con cemento Paracore utilizando el protocolo adhesivo del mismo sistema. Las muestras fueron incluidas en acrílico cristal, cortadas en forma perpendicular al eje mayor de la pieza con una máquina de corte y por último se procedió a medir los valores de adhesión de los postes a la superficie interna de los conductos en los tres tercios con la prueba push-out mediante una máquina de ensayo universal. Los resultados arrojaron que las resistencias (media +- DE, MPa) en los tercios cervical, medio y apical, fueron 8,74 +- 3,12, 9,38 +- 2,29 y 11,11 +- 2,95, respectivamente. En el tercio apical se registró mayor resistencia. Considerando las limitaciones de esta investigación, se puede concluir que la cementación de postes de fibra con cementos resinosos, presenta mayores valores en el tercio apical y menores en el tercio cervical del conducto radicular con técnica de Push-out (AU)


Subject(s)
Tensile Strength , Post and Core Technique , Flexural Strength , Bicuspid , Cementation/methods , Dentin-Bonding Agents , Tooth Cervix , Dental Pulp Cavity , Fibric Acids
5.
Braz. dent. j ; 31(4): 409-416, July-Aug. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132311

ABSTRACT

Abstract This study was conducted to evaluate whether antibacterial pretreatment irrigation with silver nanoparticles (SNPs) and silver diamine fluoride (SDF) has any effect on bond strength of fiber posts cemented with three types of resin cements in root canal space. Fifty-four endodontically treated maxillary central incisor roots were prepared for fiber post (FRC Postec Plus NO.3, Ivoclar Vivadent) cementation and divided into nine groups in terms of three cement types and two pretreatments with silver antibacterial agents. The cements were as follows: an etch-and-rinse cement (ER, Excite DSC/Variolink N), a self-etch cement (SE, ED Primer/Panavia F2.0), and a self-adhesive cement (SA, Panavia SA Luting Plus). For each cement, the control group was with no treatment and two experimental groups were with SNPs and SDF treatments that were used after acid-etching for ER cement and after EDTA treatment for SE and SA cements. After fiber post cementation, each bonded root was horizontally sectioned into 1-mm thickness microslices to create two slices for each root region (apical, middle and coronal) and underwent push-out bond strength (PBS) test. Data in MPa were analyzed with two-way ANOVA and Tukey test (p=0.05). The interaction of the pretreatment type and cement type was significant (p<0.001). SNPs and SDF significantly increased PBS with ER cement (p≤0.04). This positive effect was also marginally significant for SDF with SE cement (p=0.049). For SA cement, SNPs showed a significant positive effect, but SDF had a significant adverse effect on PBS (p<0.001). The effect of pretreatment with silver antibacterial agents prior to adhesive cementation of fiber posts depends on the resin cement used. Contrary to SNPs with beneficial or no significant effect on bonding for all cements, SDF exhibited a deleterious effect with self-adhesive cement.


Resumo Este estudo foi conduzido para avaliar se a irrigação de pré-tratamento antibacteriano com nanopartículas de prata (SNPs) e fluoreto de diamina de prata (SDF) tem algum efeito na resistência de união de pinos de fibra cimentados com três tipos de cimentos resinosos no espaço do canal radicular. Cinquenta e quatro raízes de incisivos centrais superiores tratadas endodonticamente foram preparadas para cimentação de pino de fibra (FRC Postec Plus NO.3, Ivoclar Vivadent) e divididas em nove grupos em termos de três tipos de cimento e dois pré-tratamentos com agentes antibacterianos de prata. Os cimentos foram os seguintes: um cimento etch-and-rinse (ER, Excite DSC / Variolink N), um cimento autocondicionante (SE, ED Primer / Panavia F2.0) e um cimento autoadesivo (SA, Panavia SA Luting Plus). Para cada cimento, o grupo controle foi sem tratamento e dois grupos experimentais foram com SNPs e SDF tratamentos que foram usados após o condicionamento ácido para o cimento ER e após o tratamento com EDTA para os cimentos SE e SA. Após a cimentação do pilar de fibra, cada raiz ligada foi seccionada horizontalmente em microclimas de 1 mm de espessura para criar duas fatias para cada região da raiz (apical, média e coronal) e submetida ao teste de resistência de união por push-out (PBS). Os dados em MPa foram analisados ​​com ANOVA de dois fatores e teste de Tukey (p = 0,05). A interação do tipo de pré-tratamento e tipo de cimento foi significativa (p<0,001). SNPs e SDF aumentaram significativamente o PBS com cimento ER (p≤0,04). Este efeito positivo também foi marginalmente significativo para SDF com cimento SE (p = 0,049). Para o cimento SA, os SNPs mostraram um efeito positivo significativo, mas o SDF teve um efeito adverso significativo no PBS (p <0,001). O efeito do pré-tratamento com agentes antibacterianos de prata antes da cimentação adesiva dos pinos de fibra depende do cimento resinoso utilizado. Ao contrário dos SNPs com efeito benéfico ou nenhum efeito significativo na adesão para todos os cimentos, o SDF exibiu um efeito deletério com o cimento autoadesivo.


Subject(s)
Post and Core Technique , Dental Bonding , Metal Nanoparticles , Silver , Dentin , Anti-Bacterial Agents
6.
Braz. dent. j ; 31(3): 272-280, May-June 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132305

ABSTRACT

Abstract The purpose of this study was to evaluate the influence of the application mode of three universal adhesive systems on interfacial physical properties of indirect composite restorations adhesively cemented to dentin cavities. Seventy-eight bovine lower incisors were selected and a slice of dentin (thickness: 2 mm) between the buccal surface and pulp chamber was obtained for each tooth. Conical cavities were made on this surface. The internal walls of the cavities were then coated with a hydrophilic gel, filled with composite resin and photopolymerized. The dentin/cone sets were divided into 6 groups (n=10) according to type of universal adhesive (TETRI: Tetric N Bond, FUT: Futura Bond U, SBU: Single Bond Universal) and acid etching on dentin (A: with acid etching; WA: without acid etching). The acid etching and the adhesive systems were applied to the surface of the dentin. All composite resin cones were sandblasted (Al2O3, 20 s) and silanized. After surface treatment, the cones were cemented (RelyX Ultimate) into the dentin cavity and photopolymerized. After thermocycling (10,000 cycles), samples were submitted to marginal adaptation analysis (using caries detector dye), push-out test (0.5 mm/min), and failure mode analysis. Additional samples were prepared for nanoleakage analysis (SEM). The data (MPa) were analyzed by two-way ANOVA and Tukey's post-test (5%). The groups in which the dentin was acid etched showed significantly lower bond strength values in the push-out test (p<0.01). Dentin acid etching significantly reduced the bond strength between universal adhesive systems and dentin in indirect restorative procedures.


Resumo O objetivo deste estudo foi avaliar a influência do modo de aplicação de três sistemas adesivos universais nas propriedades físicas interfaciais de restaurações indiretas de compósito adesivamente cimentadas a cavidades dentinária. Setenta e oito incisivos inferiores bovinos foram selecionados e uma fatia de dentina (espessura: 2 mm) entre a face vestibular e a câmara pulpar foi obtida para cada dente. Cavidades cônicas foram feitas nesta superfície. As paredes internas das cavidades foram então revestidas com um gel hidrofílico, preenchidas com resina composta, e fotopolimerizados. Os conjuntos dentina/cone foram divididos em 6 grupos (n=10) de acordo com o tipo de adesivo universal (TETRI: Tetric N Bond, FUT: Futura Bond U, SBU: Single Bond Universal) e ácido na dentina (A: com condicionamento ácido; WA: sem condicionamento ácido). O condicionamento ácido e os sistemas adesivos foram aplicados na superfície da dentina. Todos os cones de resina composta foram jateados (Al2O3, 20 s) e silanizados. Após o tratamento superficial, os cones foram cimentados (RelyX Ultimate) na cavidade dentinária e fotopolimerizados. Após a termociclagem (10.000 ciclos), as amostras foram submetidas a análise de adaptação marginal (usando corante detector de carie), teste push-out (0,5 mm/min) e análise do modo de falha. Amostras adicionais foram preparadas para análise de nanoinfiltração (MEV). Os dados (MPa) foram analisados por ANOVA dois fatores e pós-teste de Tukey (5%). Os grupos em que a dentina foi condicionada por ácido apresentaram valores significativamente menores de resistência de união no teste push-out (p<0,01). O condicionamento ácido da dentina reduziu significativamente a resistência de união entre sistemas adesivos universais e dentina em procedimentos restauradores indiretos.


Subject(s)
Animals , Dental Bonding , Dentin-Bonding Agents , Surface Properties , Tensile Strength , Materials Testing , Cattle , Composite Resins , Resin Cements , Dental Cements , Dental Pulp Cavity , Dentin
7.
Int. j. odontostomatol. (Print) ; 14(1): 109-116, mar. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1056509

ABSTRACT

RESUMEN: Paredes sin instrumentar y con material obturador endodóntico residual pueden elevar la posibilidad de la falla adhesiva de postes de fibroresina. Las fresas de desobturación y conformación del espacio protésico poseen una sección circular, lo que dificulta una adecuada preparación y limpieza de las paredes de los conductos ovales. El objetivo del presente estudio fue evaluar la capacidad de limpieza ultrasónica del espacio protésico y cómo ésta influyó en la resistencia a la tracción de postes de fibroresina en conductos ovales. Se utilizaron 30 premolares con conducto ovalado divididos aleatoriamente en 3 grupos de estudio (n=10), siendo: grupo A: preparación rotatoria con complemento ultrasónico, grupo B: preparación rotatoria y grupo C: grupo control. Postes de fibra de vidrio fueron cementados y luego de 7 días se realizaron cortes de un milímetro de grosor del tercio cervical y medio de cada muestra y se evaluó microscópicamente el área de gutapercha remanente y área efectiva de adhesión. Estos fueron sometidos a una prueba de push out evaluando la resistencia adhesiva de los postes. Finalmente fueron observados microscópicamente para analizar tipo de falla. Los resultados se analizaron mediante el test de ANOVA, Bonferroni, Kruskal-Wallis y Mann Whitney (p < 0.05), registrando diferencias estadísticamente significativas en la resistencia a tracción, área de gutapercha remanente y área disponible para la adhesión; además de una relación directa entre gutapercha remanente y menor resistencia a la tracción. Conclusiones: La preparación ultrasónica del espacio protésico aumenta la resistencia a la tracción de postes de fibroresinas cementados en conductos ovalados.


ABSTRACT: Untouched canal walls with residual filling materials can increase the probability of adhesive failure of fiber posts. The drills used for desobturation and conformation of the prosthetic space, has a circular cross section, which does not allow a proper preparation and cleaning of oval-shaped canal walls. The objective of the study was to evaluate the ultrasonic cleaning of the prosthetic space and how this influences the adhesive strength of fiber posts in oval-shaped canals. Thirty (30) oval-shaped canal premolars were randomly divided into 3 groups (n = 10): Group A: rotary desobturation with ultrasonic complement, group B: rotary desobturation without ultrasonic complement and group C: control group. Fiberglass posts were cemented; after 7 days, one-millimeter slices were performed, one of the cervical and another from the middle third of the root. The slices were analyzed under an optical microscope to evaluate remaining gutta percha and effective adhesion area. Samples were subjected to a push-out test to evaluate bond strength of the fiber resin posts. Finally, samples were evaluated microscopically to analyze the type of failure. The results were analyzed using ANOVA, Bonferroni, KruskalWallis and Mann Whitney test (p < 0.05), recording statistically significant differences in bond strength, remaining gutta-percha area and clean walls for adhesion; In addition, to a direct relationship between remaining gutta percha and lower adhesive strength, the ultrasonic preparation of the prosthetic space increases bond strength of fiber posts in oval canals.


Subject(s)
Humans , Osteotomy/methods , Ultrasonics , Post and Core Technique , Dental Bonding , Root Canal Preparation/instrumentation , Specimen Handling , In Vitro Techniques , Analysis of Variance , Dentin-Bonding Agents , Root Canal Preparation/methods
8.
Rev. odontol. UNESP (Online) ; 49: e20200001, 2020. tab
Article in English | LILACS, BBO | ID: biblio-1139423

ABSTRACT

Introduction: The resistance adhesive of a fiber post can be affected by several factors, such as the endodontic sealer and post-endodontic waiting time. Objective: The aim of this study was to evaluate the effect of different endodontic sealers and two different post-endodontic waiting times on the bond strength of fiber posts. Material and method: Seventy-two bovine teeth were endodontically treated and filled using three endodontic sealers: eugenol-based, epoxy resin-based, or mineral trioxide aggregate-based. The specimens were stored at 37°C for 24 hours or for 30 months. After the respective storage times, the root canals were prepared for luting fiber posts using RelyX U200. Push-out tests and analysis of failures were performed. The push-out data were analyzed by two-way analysis of variance to compare the effects of the endodontic sealer and with the t-test to compare the effects of post-endodontic waiting time. Result: The AH Plus sealer yielded the highest bond strength values at 30 months post-endodontics (11.26 Mpa) (p < 0.05), however no had difference with Endofill sealer at the same time. Endofill and MTA Fillapex sealers did not differ significantly in their effects, irrespective of the post-endodontic waiting time. Conclusion: In conclusion, the endodontic sealer used and post-endodontic waiting time affect the adhesive resistance of fiber posts. The adhesion increases significantly when the fiber post is cemented 30 months after the root canal filling, while the adhesion is reduced when cementing immediately after root canal treatment, in particular for eugenol-based endodontic sealers.


Introdução: A resistência de união de um pino de fibra pode ser afetada por vários fatores, como o cimento endodôntico e o tempo de espera pós-endodontia. Objetivo: Avaliar o efeito de diferentes cimentos endodônticos e dois tempos de espera pós-endodontia na resistência de união de pinos de fibra. Material e método: Setenta e dois dentes bovinos foram tratados endodonticamente e obturados usando três cimentos endodônticos: à base de eugenol, à base de resina epóxia ou à base de mineral trióxido agregado. Os espécimes foram armazenados a 37 ° C por 24 horas ou por 30 meses. Após, os canais radiculares foram preparados para cimentação dos pinos de fibra usando o RelyX U200. Foram realizados testes de push-out e análise de falhas. Os dados foram analisados por análise de variância bidirecional e com o teste t. Resultado: O cimento AH Plus obteve os maiores valores de resistência de união aos 30 meses pós-endodontia (11,26 Mpa) (p <0,05), no entanto, não houve diferença com o cimento Endofill no mesmo tempo. Os cimentos Endofill e MTA Fillapex não diferiram significativamente em seus efeitos, independentemente do tempo de espera pós-endodontia. Conclusão: O cimento endodôntico utilizado e o tempo de espera pós-endodontia afetam a resistência adesiva dos pinos de fibra. A adesão aumenta significativamente quando o pino de fibra é cimentado 30 meses após a obturação do canal radicular, enquanto a adesão é reduzida ao cimentar imediatamente após o tratamento do canal radicular, principalmente para cimentos endodônticos à base de eugenol.


Subject(s)
Cattle , Root Canal Obturation , Root Canal Therapy , Eugenol , Dental Cements , Dental Pins , Epoxy Resins , Analysis of Variance
9.
Arq. odontol ; 56: 1-8, jan.-dez. 2020. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1097768

ABSTRACT

Aim: To evaluate the influence of lengths and different luting agents on the bond strength of fiberglass posts' adhesion to dentin.Methods: Sixty single-root bovine teeth were endodontically treated and included in polyether and acrilyc resin to simulate a periodontal ligament. These were divided into 6 groups according to the post lengths (6, 10 or 14 mm) and luting agents (self-adhesive dual resin cement ­ U; or etch-and-rinse dual resin cement ­ A): U6, U10, U14, A6, A19, and A14. All fiberglass posts were cemented according to manufacturer instructions. After this, mechanical aging was performed (1.2x106 cycles; 4 Hz, 90 N). The push-out specimens were then conducted (2.0 ± 0.1 mm), with the test executed in a universal machine (10 kgf at 0.5 mm/min). Data obtained were submitted to the Kruskal-Wallis and Dunn's test. Results: No statistically significant difference was observed in bond strength between the groups due to the type of luting agent (p > 0.05). However, the isolated post-length factor showed significantly different results for the U groups (p < 0.05). The U10 group showed similar union values to U6 but statistically inferior to U14. Conclusion: bond strength of fiberglass posts of the same length as the dentin presented no differences according to the luting agent, but the post-length property influenced the bond strength when self-adhesive resin cement was used.


Objetivo: avaliar a influência dos agentes cimentantes e dos diferentes comprimentos de pinos na resistência de união de pinos de fibra de vidro a dentina. Métodos: Sessenta dentes bovinos uniradiculares tiveram a raiz endodonticamente tratada, e foram incluídos em poliéter e resina acrílica para simular o ligamento periodontal. Os espécimes foram divididos em seis grupos de acordo com o comprimento dos pinos (6, 10 ou 14mm) e dos agentes de cimentantes (cimento resinoso dual autoadesivo (RelyX U200, 3M ESPE) - U; ou cimento resinoso dual convencional (AllCem Core, FGM) - A: U6, U10, U14, A6, A19 e A14. Todos os pinos de fibra de vidro foram cimentados conforme as recomendações do fabricante. Após, o envelhecimento mecânico (1,2x106 ciclos; 4 Hz, 90 N) as amostras foram fatiadas para o teste de push-out (2,0 ± 0,1 mm) executado em uma máquina de ensaio universal (10 kgf a 0,5 mm/min). Os dados foram submetidos ao teste de Kruskal-Wallis e Dunn. Resultados: não houve diferença estatística na resistência de união entre os grupos devido ao tipo de agente cimentante (p > 0,05), mas houve para o comprimento dos pinos dos grupos U (p < 0,05). O grupo U10 apresentou valores de união semelhantes a U6, mas estatisticamente inferiores ao U14. Conclusão: a resistência de união dos pinos de fibra de vidro de um mesmo comprimento não apresentou diferenças mesmo quando cimentados com cimentos diferentes, mas o comprimento dos pinos isoladamente influenciou quando o cimento resinoso autoadesivo foi utilizado.


Subject(s)
Acrylic Resins , Materials Testing , Resin Cements , Dental Cements , Materials Science , Glass Ionomer Cements , Dental Pins
10.
Odovtos (En línea) ; 21(2): 63-72, May.-Aug. 2019. tab, graf
Article in English | LILACS, BBO | ID: biblio-1091482

ABSTRACT

ABSTRACT The purpose of this preliminary study is to evaluate the push-out bond strength (PBS) of experimental dentin posts (EDPs) obtained from human and bovine teeth sterilized by autoclaving and gamma radiation. Eighty-four mandibulary premolars were obturated and divided into three post groups: the glass fiber group (Fb) human EDP group (Hm) and the bovine EDP group (Bv). Three subgroups (n=12) were obtained for each EDP groups according to the sterilization methods; no sterilization (Cnt), steam autoclaving (Aut), and gamma radiation (Rad) a total dose of 25 kGy. All posts were cemented to root canals using a dual cured resin cement (Panavia SA). After the micro slices (1mm in thickness) were obtained of each subgroup, PBS test was performed. Data were analyzed using two-way ANOVA and Tukey's multiple comparison tests (α=.05). The post type and sterilization method was significantly effective on the PBS values according to the ANOVA (P<.001). No sterilization apllied EDP groups showed significantly higher PBS values than the sterilized groups (P<.001). Bv_Cnt (9.42 ±1.31) showed significantly lower PBS values than both Fb (12.36 ±1.54) and Hm_Cnt (11.06 ±1.38) groups (P<.001). Both steam autoclaving and gamma radiation affect the PBS values and fracture modes of EDPs negatively. The bovine EDPs are not as effective as human EDPs with regard to the PBS to the root dentin.


RESUMEN El propósito de este estudio preliminar es evaluar el push-out bond strength de los postes de dentina experimentales (PDE) obtenidos de dientes humanos y bovinos esterilizados por autoclave y radiación gamma. Ochenta y cuatro premolares mandibulares fueron obturadores y se dividieron en tres grupos experimentales de postes: el grupo de fibra de vidrio (Fb) grupo PDE humano (Hm) y el grupo PDE bovino (Bv). Se obtuvieron tres subgrupos (n=12) para cada grupo de PDE según los métodos de esterilización; sin esterilización (Cnt), autoclave a vapor (Aut) y radiación gamma (Rad) con una dosis total de 25 kGy. Todos los postes se cementaron a los conductos radiculares utilizando un cemento de resina de curado doble (Panavia SA). Después de que se obtuvieron las micro rebanadas (1 mm de espesor) de cada subgrupo, se realizó una prueba de push-out bond strength. Los datos se analizaron utilizando ANOVA de dos vías y las pruebas de comparación múltiple de Tukey (α=.05). El tipo de poste y el método de esterilización fueron significativamente efectivos en los valores de push-out bond strength según el ANOVA (P <.001). Los grupos de PDE no aplicados a la esterilización mostraron valores de push-out bond strength significativamente mayores que los grupos esterilizados (p <0,001). Bv_Cnt (9.42 ±1.31) mostró valores de push-out bond strength significativamente más bajos que los grupos Fb (12.36 ±1.54) y Hm_Cnt (11.06 ±1.38) (P <.001). Tanto el autoclave al vapor como la radiación gamma afectan negativamente los valores de push-out bond strength y los modos de fractura de los PDE. Los PDE bovinos no son tan efectivos como los PDE humanos con respecto a la fuerza de adhesión a la dentina de la raíz.


Subject(s)
Sterilization/methods , Dentin/drug effects , Tooth/radiation effects , Dental Materials , Radiation Equipment and Supplies
11.
Braz. dent. j ; 30(2): 106-116, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1001439

ABSTRACT

Abstract The aim of this study was to evaluate the push-out bond strength and interface permeability of glass-fiber posts in different regions of post space (cervical, middle, and apical) submitted to different irrigation solutions. Ninety single-rooted human teeth were submitted to endodontic treatment and divided into five groups, according to irrigation solutions: distilled water, 5.25% NaOCl, 25% polyacrylic acid, 2% chlorhexidine, and 23 ppm Ag NP dispersion. Each group was divided in 3 subgroups (n=6) according to cementation: SBU: Adper Scotchbond Universal + RelyX ARC; U200: RelyX U200; MCE: MaxCem Elite. Bond strength and sealing ability were measured in different areas of post space. The data was subjected to ANOVA and Fisher's test (a=0,05). The silver nanoparticle solution showed highest bond strength values and lowest interface permeability in all thirds analyzed for SBU group. In the U200 group, the highest bond strength values were found for sodium hypochlorite solution, with significant difference between this solution and polyacrylic acid. A decrease in bond strength values in cervical to apical direction was found for MCE group and the same behavior were found for others groups. Regarding interface permeability, use of silver nanoparticle solution resulted in lower values in cervical and apical thirds. There was a decrease in bond strength in cervical to apical direction. Different irrigation solutions and intraradicular depth influenced the bond strength and interface permeability of adhesive material to dentin substrate. Silver nanoparticle solution can effectively be used as an irrigation agent in post space prior to fiber post cementation process.


Resumo O objetivo deste trabalho foi avaliar a resistência de união e permeabilidade da interface de pinos de fibra de vidro nos diferentes terços da dentina intrarradicular (cervical, médio e apical) submetidos a diferentes agentes irrigantes. Noventa dentes unirradiculares humanos foram submetidos ao tratamento endodôntico e foram divididos em cinco grupos de acordo com os agentes irrigantes: água destilada, hipoclorito de sódio 5,25%, ácido poliacrílico 25%, clorexidina 2% e dispersão de nanopartícula de prata à 23 ppm. Os grupos foram divididos em 3 subgrupos (n=6) de acordo com a técnica adotada para cimentação adesiva dos pinos de fibra de vidro: Grupo SBU: sistema adesivo ScotchbondTM Universal + cimento resinoso RelyX ARC; Grupo U200: cimento resinoso autoadesivo RelyX U200; Grupo MCE: cimento resinoso autoadesivo Maxcem Elite. A resistência de união e a permeabilidade da interface foram mensurados em diferentes áreas da dentina intrarradicular. Os dados foram submetidos a ANOVA e teste de Fisher (a=0,05). Amostras representativas foram levadas à microscopia eletrônica de varredura. A solução de nanopartícula de prata apresentou os maiores valores de resistência de união em todos os terços analisados para o grupo SBU. No grupo U200, os maiores valores foram encontrados para a solução de hipoclorito de sódio, com diferença para o ácido poliacrílico. Observou-se uma diminuição nos valores de resistência de união na direção cérvico-apical para o grupo MCE e o mesmo comportamento foram encontrados para os demais grupos. Com relação a permeabilidade da interface, o uso da solução de nanopartícula de prata resultou em menores valores nos terços cervical e apical. Houve diminuição dos valores de resistência de união no sentido cérvico-apical. As diferentes soluções irrigantes, bem como a profundidade intrarradicular influenciaram a resistência de união e permeabilidade da interface dos materiais adesivos ao substrato dentinário. A nanopartícula de prata pode ser utilizada como agente irrigador do conduto radicular previamente à cimentação de pinos de fibra de vidro.


Subject(s)
Humans , Post and Core Technique , Dental Bonding , Metal Nanoparticles , Silver , Materials Testing , Resin Cements , Dentin , Glass
12.
Restorative Dentistry & Endodontics ; : e5-2019.
Article in English | WPRIM | ID: wpr-741986

ABSTRACT

OBJECTIVES: The aim of this in vitro study was to evaluate the push-out bond strength of a novel calcium silicate-based root repair material-BIOfactor MTA to root canal dentin in comparison with white MTA-Angelus (Angelus) and Biodentine (Septodont). MATERIALS AND METHODS: The coronal parts of 12 central incisors were removed and the roots were embedded in acrylic resin blocks. Midroot dentin of each sample was horizontally sectioned into 1.1 mm slices and 3 slices were obtained from each root. Three canal-like standardized holes having 1 mm in diameter were created parallel to the root canal on each dentin slice with a diamond bur. The holes were filled with MTA-Angelus, Biodentine, or BIOfactor MTA. Wet gauze was placed over the specimens and samples were stored in an incubator at 37°C for 7 days to allow complete setting. Then samples were subjected to the push-out test method using a universal test machine with the loading speed of 1 mm/min. Data was statistically analyzed using Friedman test and post hoc Wilcoxon signed rank test with Bonferroni correction. RESULTS: There were no significant differences among the push-out bond strength values of MTA-Angelus, Biodentine, and BIOfactor MTA (p > 0.017). Most of the specimens exhibited cohesive failure in all groups, with the highest rate found in Biodentine group. CONCLUSIONS: Based on the results of this study, MTA-Angelus, Biodentine, and BIOfactor MTA showed similar resistances to the push-out testing.


Subject(s)
Calcium , Dental Instruments , Dental Pulp Cavity , Dentin , In Vitro Techniques , Incisor , Incubators , Methods , Miners , Pemetrexed
13.
RFO UPF ; 23(2): 206-210, 24/10/2018. tab
Article in Portuguese | LILACS, BBO | ID: biblio-947595

ABSTRACT

Objetivo: avaliar o efeito do uso de hipoclorito de cálcio (Ca(OCl)2) como irrigante na resistência de adesão do cimento AH Plus (De Trey-Dentsply, Konstanz, Alemanha) à dentina pelo teste de micro push-out. Materiais e método: trinta e três dentes humanos monorradiculares foram seccionados transversalmente na junção amelocementária e divididos em três grupos: hipoclorito de sódio (NaOCl) 2,5%, hipoclorito de cálcio 2,5% e soro fisiológico. Os canais foram preparados, irrigados ao final com EDTA 17% e obturados com cones de guta percha e cimento AH Plus. Após armazenagem por 7 dias, em 100% de umidade e a 37°C, os dentes foram seccionados transversalmente ao longo do eixo da raiz. Foram obtidas três fatias de cada dente (n=33), que foram submetidas ao ensaio de push-out. O tipo de falha foi analisado por fractografia e classificado em falha adesiva, coesiva ou mista. Os valores de resistência de união foram analisados pelo teste de Kruskal-Wallis, com nível de significância de 95%. Resultados: o grupo Ca(OCl)2 2,5% apresentou a menor média de resistência de adesão, diferindo estatisticamente do NaOCl e do soro fisiológico (p<0,05). Não houve diferença estatística entre os grupos irrigados com soro e NaOCl (p>0,05). Conclusões: a falha predominante em todos os grupos foi a do tipo adesiva. O Ca(OCl)2 2,5% teve um efeito negativo sobre a força de adesão do AH Plus à dentina radicular quando comparado ao NaOCl 2,5%. (AU)


Objective: to evaluate the effect of calcium hypochlorite (Ca(OCl)2) as an irrigant on the bond strength of the AH Plus sealer (De Trey-Dentsply, Konstanz, Germany) to dentin, using the micro push-out test. Materials and method: thirty-three single-rooted human teeth were cross-sectioned on the cementoenamel junction and divided into three groups: 2.5% sodium hypochlorite (Na- OCl), 2.5% calcium hypochlorite, and saline solution. The canals were prepared, irrigated with 17% EDTA at the end, and filled with gutta-percha cones and AH Plus sealer. After being stored for seven days at 100% humidity and 37ºC, the teeth were cross-sectioned along the root axis. Three slices of each tooth (n=33) were obtained and subjected to the push-out test. Failure mode was analyzed by fractography and classified as adhesive, cohesive, or mixed. Bond strength values were analyzed by the Kruskall-Wallis test at 95% significance level. Results: the 2.5% Ca(OCl)2 group showed the lowest bond strength mean, differing statistically from 2.5% NaOCl and saline solution (p<0.05). There was no statistical difference between the groups irrigated with saline solution and NaOCl (p>0.05). Conclusion: the adhesive failure was predominant in all groups. The 2.5% Ca(OCl)2 had a negative effect on the bond strength of AH Plus to the root dentin when compared to 2.5% NaOCl. (AU)


Subject(s)
Humans , Root Canal Filling Materials/chemistry , Root Canal Obturation/methods , Epoxy Resins/chemistry , Calcium Hypochlorite , Tooth Fractures , Edetic Acid/chemistry , Statistics, Nonparametric , Dental Restoration Failure , Flexural Strength
14.
Braz. dent. j ; 29(2): 189-194, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-951539

ABSTRACT

Abstract This study investigated the effect of blood-contamination on the push-out bond strength of BiodentineTM (BD) and MTA Angelus® (MTA-A) to root dentin over time. Twenty-five teeth were sectioned horizontally to obtain 120 root slices. The lumens were filled with MTA-A or BD: 60 for each cement (30 uncontaminated and 30 blood contaminated). Push out bond strength to dentin was assessed at 24 h (n=10), 7 days (n=10) and 28 days (n=10). Failure modes were classified as: cohesive, adhesive or mixed failure. Two-way ANOVA was used to investigate the interaction between blood contamination vs. hydration period. Mann Whitney test compared different materials in each period, and it also compared the contaminated versus uncontaminated material for each period. Friedman, followed by Dunn`s test, compared periods of hydration for each material, regardless of blood contamination. Failure modes were reported descriptively. The interaction hydration period vs. blood contamination was highly significant for MTA-A (P=0.001) and it was not significant for BD (P=0.474). There were no differences between bond strength of uncontaminated and contaminated BD in any of the periods. Bond strength of uncontaminated MTA-A increased at each time of hydration; but it remained stable over time for blood-contaminated samples. BD had higher bond strength than MTA-A in all periods of hydration. Cohesive failure predominated. Only for MTA-A, the over time bond strength to dentin was affected by blood contamination.


Resumo Este estudo investigou o efeito da contaminação sanguínea na resistência de união do BiodentineTM (BD) e do MTA Angelus® (MTA-A) à dentina, em diferentes períodos. Vinte e cinco dentes foram seccionados para obter 120 fatias de dentina. Os lúmens das fatias foram preenchidos com MTA-A ou BD: 60 para cada cimento (30 não-contaminados e 30 contaminados com sangue). A resistência de união à dentina foi medida por teste push-out em 24 horas (n=10), 7 dias (n=10) e 28 dias (n=10). Os tipos de falha foram classificados como: falha coesiva, adesiva ou mista. Two-way ANOVA foi usado para investigar a interação entre contaminação sanguínea vs. período de hidratação. O teste de Mann Whitney comparou os diferentes materiais em cada período, e comparou as amostras contaminadas e não contaminadas de cada material em cada tempo. O teste de Friedman, seguido pelo teste de Dunn, comparou os períodos de hidratação de cada material, independentemente da contaminação. A análise estatística mostrou a interação entre contaminação sanguínea vs. período de hidratação. Os tipos de falha foram reportados de maneira descritiva. A interação entre contaminação sanguínea vs. período de hidratação foi altamente significativa para o MTA-A (P=0,001), e não foi significativa para o BD (P=0,474). Não houve diferenças entre a resistência de união entre o BD contaminado e não-contaminado independente do período. A resistência de união do MTA-A não-contaminado aumentou a cada tempo de hidratação; mas, permaneceu estável ao longo do tempo para as amostras contaminadas com sangue. BD obteve maior resistência de união que o MTA-A em todos os períodos de hidratação. Falhas coesivas predominaram. A contaminação ao longo do tempo influenciou a resistência de união no grupo MTA-A.


Subject(s)
Humans , Blood , Materials Testing , Dentin-Bonding Agents/chemistry , Calcium Compounds/chemistry , Aluminum Compounds/chemistry , Dental Cements/chemistry , Oxides/chemistry , Silicates/chemistry , Dental Stress Analysis , Drug Combinations
15.
Braz. dent. j ; 29(2): 195-201, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-951536

ABSTRACT

Abstract This study investigated the bond strength of two experimental root canal sealers based on MTA and butyl ethylene glycol disalicylate: MTAe and MTAe-HA. The reference materials used for comparison were AH Plus and MTA Fillapex. Twenty human upper incisors were selected and one 1 mm slice was obtained from the cervical third of each root. On the coronal surface of each slice, four 0.9 mm wide holes were drilled through the dentine. Standardized irrigation was performed and holes were filled with one of the four tested sealers: AH Plus, MTA Fillapex, MTAe, and MTAe-HA. The filled slices were stored in a PBS solution (pH 7.2) for 7 days at 37 °C. A push-out assessment was performed with a 0.7 mm plunger tip. Load was applied at a crosshead speed of 0.5 mm/min until sealer displacement. The results were expressed in MPa. The Kruskal-Wallis test was applied to assess the effect of each sealer on the push-out bond strength. Mann-Whitney with Bonferroni correction was used to isolate the differences. The alpha-type error was set at 0.05. Significant differences among medians values obtained by materials were observed (p<0.001). AH Plus displayed the highest value of bond strength (p<0.001). In contrast, MTA Fillapex presented the lowest bond strength among all tested sealers (p<0.001). Experimental sealers showed intermediary bond strength values, with no statistical differences between them (p>0.05). In conclusion, experimental root canal sealers presented suitable bond strength outcomes when compared to MTA Fillapex.


Resumo Esse estudo investigou a resistência de união de dois cimentos endodônticos experimentais à base de MTA e butiletilenoglicol dissalicilato: MTAe e MTAe. Os materiais de referência utilizados para comparação foram os cimentos endodônticos MTA Fillapex e AH Plus. Vinte incisivos superiores humanos foram selecionados e um slice dentinário de 1 mm de espessura foi obtido do terço cervical de cada raiz. Na superfície coronária de cada slice, quatro orifícios com 0,9 mm de diâmetro foram confeccionados através da dentina. Uma irrigação padronizada foi realizada e os orifícios foram preenchidos com um dos quatro cimentos endodônticos avaliados: AH Plus, MTA Fillapex, MTAe, e MTAe-HA. Os slices preenchidos foram armazenados em solução PBS (pH 7,2) durante 7 dias a 37°C. O ensaio de push-out foi realizado por meio de um dispositivo com 0,7 mm de diâmetro. A carga foi aplicada com a velocidade de 0,5 mm/min até a obtenção de deslocamento do material obturador. Os resultados foram expressos em MPa. O teste de Kruskal-Wallis foi aplicado para avaliar o efeito da resistência de união de cada cimento endodôntico. O teste de Mann-Whitney com correção de Bonferroni foi utilizado para isolamento das diferenças. O erro do tipo-alfa foi fixado em 0,05. Diferenças significantes entre os valores de medianas obtidos pelos materiais foram observados (p<0,001). O AH Plus demonstrou os maiores valores de resistência de união (p<0,001). Em contraste, o MTA Fillapex apresentou a menor resistência de união entre todos os cimentos testados (p<0,001). Os cimentos experimentais demonstraram valores intermediários, com ausência de diferenças estatísticas entre si (p>0,05). Em conclusão, os cimentos endodônticos experimentais à base de MTA e butiletilenoglicol dissalicilato apresentaram resultados adequados de resistência de união quando comparados ao MTA Fillapex.


Subject(s)
Humans , Oxides/chemistry , Materials Testing , Calcium Compounds/chemistry , Aluminum Compounds/chemistry , Ethylene Glycol/chemistry , Ethylene Glycols/chemistry , Root Canal Filling Materials/chemistry , Salicylates/chemistry , Dental Bonding/methods , Silicates/chemistry , Drug Combinations
16.
Article | IMSEAR | ID: sea-187649

ABSTRACT

Background: Sealers are universally used along with gutta-percha to obturate the root canals in three dimensions. Push-out bond strength is considered appropriate to measure the adhesion capacity of sealers. Aim: To compare the bond strength of recently introduced bioceramic sealer with commonly used sealers and to evaluate the effect of plunger: base orifice size ratio on push-out bond strength. Methods:One hundred mandibular premolars with single canals were decoronated and instrumented up to master apical file F3 Protaper. Specimens were randomly divided into four groups (n=25) based on the sealer used: Group 1-EndoSequence BC Sealer, Group 2-MTA FillApex sealer, Group3-Apexit Plus sealer & Group 4-AH Plus sealer and obturated using cold lateral compaction technique. After two weeks, 1±0.1mm thick slice of each radicular third of specimens was subjected to push-out testing with modified and standardised plunger: base orifice size ratio for each slice and bond strength calculated. Subsequently the slices were observed under stereomicroscope for failure mode analysis. Results: Results showed that AH Plus sealer had the highest overall bond strength followed by EndoSequence BC sealer and MTA FillApex while as Apexit Plus had lowest bond strength. Bond strength of all sealers reduced from coronal to apical direction except in EndoSequence BC sealer which showed better strength in critical apical third. Higher bond strength values were obtained due to modified relation of plunger with base orifice size. Conclusion: Bond strength of all sealers tested except EndoSequence BC reduces in apical direction and is impacted by plunger: base orifice size ratio.

17.
Journal of Korean Academy of Pediatric Dentistry ; (4): 455-463, 2018.
Article in Korean | WPRIM | ID: wpr-787341

ABSTRACT

The purpose of this study was to evaluate the effect of the intracanal medicaments on the push-out bond strength of the calcium silicate-based materials.Forty extracted single-root human mandibular premolars were sectioned below cementoenamel junction. Standardized root canal dimension was obtained with a parallel post drill. The specimens were randomly divided into a control group (no medicament), and experimental groups received medicaments with either CH (calcium hydroxide), DAP (double antibiotic paste; a mixture of ciprofloxacin and metronidazole), or TAP (triple antibiotic paste; a mixture of minocycline, ciprofloxacin and metronidazole). Following removal of medicaments with irrigation, roots were cut into sections with 1-mm-thickness. Thereafter, calcium silicate-based materials are applied to the specimens : (i) ProRoot MTA® and (ii) Biodentine®. A push-out bond strength was measured and each specimen was examined to evaluate failure mode.Intracanal medication using CH significantly increased the bond strength to the root dentin. But there are no significant differences on the bond strength of ProRoot MTA® or Biodentine® among TAP, DAP and control groups. The dislodgement resistance of Biodentine® from root dentin was significantly higher than that of ProRoot MTA® regardless of the type of intracanal medicaments.


Subject(s)
Humans , Bicuspid , Calcium , Ciprofloxacin , Dental Pulp Cavity , Dentin , Minocycline , Tooth Cervix
18.
Odovtos (En línea) ; 19(2)ago. 2017.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1506904

ABSTRACT

ctualmente existe controversia en la literatura acerca de la efectividad clínica y adhesiva con respecto a los sistemas adhesivos de refuerzo radicular. Así, el objetivo de este estudio fue evaluar la resistencia de unión mediante la prueba de Push-Out entre el sistema de postes Rebilda® y la dentina intraradicular. Para esto, se utilizaron 28 dientes unirradiculares, que fueron cortados y padronizados en 16 mm. Los segmentos radiculares fueron sometidos a confección de tratamiento endodóntico; posteriormente, se dividieron aleatoriamente en dos grupos, Grupo 1 (n=14): Rebilda® DC+Futurabond DC; Grupo 2 (n=14): RelyX ARC+Adper Scothbond Multipropósito Plus. Seguidamente, diez especímenes de cada grupo se cortaron para ser sometidos al Test de Push-Out. Los restantes 4 especímenes de cada grupo se prepararon para Microscopia Electronica de Barrido con el fin de evaluar la formación de prolongaciones resinosas en la interface poste-cemento-dentina. El grupo 2 obtuvo mejores resultados al compararlo al Grupo 1 en cuanto a resistencia de unión y en formación de prolongaciones resinosas, pero no hubo diferencia estadísticamente significativa (p>0.05). Se concluyó que el Sistema de Postes REBILDA® promueve una adecuada resistencia de unión a dentina intrarradicular.


urrently there is controversy in the literature about clinical and adhesive effectiveness with respect to adhesive systems aimed to root reinforcement. Thus, the objective of this study was to evaluate the Push-Out bond strength between the Rebilda® post system and the intraradicular dentine. Thus, 28 unirradicular teeth were used, cut and standardized in 16 mm. The root segments were submitted to endodontic treatment; and then randomly divided into two groups, Group 1 (n = 14): Rebilda® DC + Futurabond DC; Group 2 (n = 14): RelyX ARC + Adper Scothbond Multipurpose Plus. Ten specimens from each group were submitted to the Push-Out Test. The remaining 4 specimens from each group were prepared for Scanning Electron Microscopy (SEM) in order to evaluate the formation of resinous extensions at the post-cement-dentin interface. Group 2 showed better results when compared to Group 1 regarding bond strength and in formation of resinous extensions or tags, but there was no statistically significant difference (p>0.05). It was concluded that the REBILDA® Post System promotes adequate bond strength to intraradicular dentin.

19.
Journal of Practical Stomatology ; (6): 174-178, 2017.
Article in Chinese | WPRIM | ID: wpr-619254

ABSTRACT

Objective:To evaluate the effect of epigallocatechin-3-gallate (EGCG) and epigallocatechin-3-O-(3-O-methyl)-gallate (EGCG-3Me) on the anti-bacterial effect and the stability of intraradicular dentin-adhesive interface.Methods:EGCG and EGCG3Me with the concentration of 400 μg/ml were incorporated into Single Bond 2 (SB2) respectively to obtain 2 modified adhesives E-SB2 and E3-SB2.Confocal laser scanning microscopy(CLSM) and ultraviolet spectrophotometry were used to evaluate the anti-bacterial effect of the modified adhesives.Micro-Raman spectrum was used to test the degree of conversion (DC) of the adhesives.Push-out bond strength test was conducted to examine the immediate bond strength and the bond strength after themocycling.Results:E-SB2 and E3-SB2 both showed inhibiting effect on the proliferation of E.faecalis,while E3-SB2 performed stronger inhibiting effect.DC and the immediate push-out bond strength of SB2 were not decreased with the incorporation of EGCG or EGCG-3Me(P > 0.05).E-SB2 and E3-SB2 showed significantly higher push-out bond strengths than that of SB2 (P < 0.05) after themocycling.Conclusion:EGCG and EGCG-3Me modified adhesives have anti-bacterial effect and can enhance the stability of bonding between intraradicular dentin and adhesive,EGCG-3Me may have stronger anti-bacterial effect.

20.
Braz. dent. sci ; 20(2): 85-92, 2017. ilus, tab, graf
Article in English | LILACS, BBO | ID: biblio-846427

ABSTRACT

Objective: To evaluate the effect of different irrigation solutions prior to post cementation on the resin bonding to bovine root dentine. Material and Methods: 60 bovine roots (16 mm) were prepared to 12 mm with specific drill of a double-tapered fiber post system, included in PMMA, and divided into 6 groups, considering the irrigation solutions (IS) prior to cementation: Gr1- saline solution (control), Gr2- NaOCl 0.5 %, Gr3- NaOCl 1 %, Gr4- NaOCl 2.5 %, Gr5- NaOCl 5 %, Gr6- Chlorexidine 2 % (solution). The root canals were irrigated with IS 20 ml during 10 min. Then they were rinsed with 20 ml of distilled water and dried with paper points. One fiber post was molded with polyvinylsiloxane and 60 posts made of resin cement (PRC) were obtained moments before the cementation. The root canal dentin was etched with H2PO3 37 %/15 s + washing/drying, a multi-bottle etch&rinse adhesive system was applied and the PRC were resin luted with dual resin cement (DuolinkTM, Bisco). Each specimen was cut into 4 slices of ±1.8mm in thickness and submitted to push-out test (1 mm/min). Results: ANOVA showed that bond strength was significantly affected by IS (P < 0.0001). The highest bond strengths (MPa) were those for the groups 4 (3.51 ± 1.52) and 5 (3.0 ± 1.16). The groups 1 (0.70 ± 0.30), 2 (0.80 ± 0.24), 3 (1.26 ± 0.57) and 6 (0.90 ± 0.41) were statistically similar to each other. Conclusion: The resin bonding to the root dentine was higher when higher concentrations of hypochlorite solutions were used. (AU)


Objetivo: Avaliar o efeito de diferentes soluções de irrigação antes da cimentação do pino na resistência de união da resina à dentina radicular bovina. Material e Métodos: Foram preparadas 60 raízes bovinas (16 mm) a 12 mm com broca específica de um sistema de pino de fibra com dupla conicidade, incluídas no PMMA, e divididas em 6 grupos, considerando as soluções irrigadoras (IS) antes da cimentação: Gr1-Solução salina (controle), Gr2-NaOCl 0,5 %, Gr3-NaOCl 1 %, Gr4-NaOCl 2,5 %, Gr5-NaOCl 5 %, Gr6-Clorexidina 2 % (solução). Os canais radiculares foram irrigados com 20 ml de IS durante 10 min. Depois, foram lavados com 20 ml de água destilada e secos com pontas de papel. Um pino de fibra foi moldado com polivinilsiloxano e 60 pinos de cimento resinoso (PRC) foram obtidos momentos antes da cimentação. A dentina radicular foi condicionada com H2PO3 37 %/15 s + lavagem/ secagem, aplicou-se o sistema de adesivo e o PRC foi cimentado com cimento resinoso dual (DuolinkTM, Bisco). Cada amostra foi cortada em 4 fatias de ± 1,8 mm de espessura e submetida a teste push-out (1 mm/ min). Resultados: ANOVA mostrou que a força de união foi significativamente afetada pelo IS (P< 0,0001). As maiores resistências de união (MPa) foram para os grupos 4 (3,51 ± 1,52) e 5 (3,0 ± 1,16). Os grupos 1 (0,70 ± 0,30), 2 (0,80 ± 0,24), 3 (1,26 ± 0,57) e 6 (0,90 ± 0,41) foram estatisticamente semelhantes entre si. Conclusão: A resistência de união da resina à dentina radicular foi maior quando foram utilizadas concentrações maiores de soluções de hipoclorito. (AU)


Subject(s)
Animals , Cattle , Dentin , Resin Cements
SELECTION OF CITATIONS
SEARCH DETAIL